Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
PLOS Glob Public Health ; 4(5): e0003153, 2024.
Article in English | MEDLINE | ID: mdl-38728356

ABSTRACT

As of December 2022, Cameroon had observed a slight resurgence of COVID-19, raising concerns on genomic surveillance of related-SARS-CoV-2 variants under circulation. Following a laboratory-based survey, positive SARS-CoV-2 samples detected from December-2022 through March-2023 were processed for targeted sequencing at the Chantal BIYA International Reference Centre (CIRCB) in Yaoundé-Cameroon. From all positive cases detected, 13 were successfully sequenced (mean age 34 years, 70% female); the majority of the cases were unvaccinated (70%, 9/13) and symptomatic (92%, 12/13); all with flu-like symptoms (100%, 12/12). Following RT-PCR, the median cycle threshold was 22.23 [18-24] for the N gene; and 24.09 [20-26] for the ORF gene, underscoring high viral loads. Phylogenetic analysis of nucleotide sequences identified four major sub-variants in circulation, of which BA.5 (3/13), the recombinants BQ.1.1 (4/13), XBB.1 (4/13) and novel atypical variant of BA.4.6/XBB.1 (2/13). This snapshot surveillance indicates the introduction/emergence and circulation of new Omicron sub-variants, all accompanied by minor/mild symptoms. However, these new sub-variants and recombinants call for continuous genomic surveillance to prevent further resurgence of Covid-19 epidemiological wave.

2.
Heliyon ; 10(9): e29937, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38694118

ABSTRACT

Background: WHO recommends the use of COVID-19 antigen rapid diagnostic tests (Ag-RDT) with at least 80 % sensitivity and 97 % specificity. In the era of Omicron variants, we sought to ascertain the performance of the INDICAID™ Ag-RDT compared to real-time PCR (RT-PCR) as the gold standard. Methods: A laboratory-based study was conducted among consenting individuals tested for COVID-19 at the virology laboratory of the Chantal BIYA International Reference Centre, Yaoundé-Cameron. The samples were processed by INDICAID™ Ag-RDT and DaAn Gene real-time PCR according to the manufacturer's instructions, and PCR-results were interpreted as per cycle thresholds (CT). The sensitivity, specificity, positive and negative predictive values (PPV and NVP) of INDICAID™ Ag-RDT were evaluated according to PCR CT-values. Results: A total of 565 nasopharyngeal swabs were collected from participants (median age [IQR]: 40 [31-75]; M/F sex-ratio was 1.2 and 380 were vaccinated). Following PCR, overall COVID-19 positivity was 5.66 %. For CT < 37, INDICAID™ Ag-RDT sensitivity was 21.9 % (95%CI: [8.3-39.9]), specificity 100 % (95%CI: [99.3-100]); PPV 100 % (95%CI: [59.0-100]), NPV 95.5 % (95%CI: [93.4-97.1]) and kappa = 0.34 (95%CI: [0.19-0.35]). For CT < 25, sensitivity was 100 % (95%CI: [47.8-100.0]), specificity 99.6 % (95%CI: [98.7-99.9]); PPV 94.4 % (95%CI: [51.7-100]), NPV 100 % (95%CI: [99.3-100]) and kappa = 0.83 (95%CI: [0.6-1.0]). COVID-19 sequences generated were all Omicron BA.1 subvariants. Conclusion: For patients infected with high viral loads (CT < 25), INDICAID™ Ag-RDT has high intrinsic (sensitivity and specificity) and extrinsic (predictive values) performances for COVID-19 diagnosis. Due to its simplicity and short turnaround time, INDICAID™ Ag-RDT is, therefore a reliable tool to prevent the spread of COVID-19 at community level in the current era of Omicron subvariants.

3.
Front Public Health ; 12: 1288139, 2024.
Article in English | MEDLINE | ID: mdl-38532968

ABSTRACT

Introduction: An increased incidence of human Monkeypox (Mpox) cases was recently observed worldwide, including in Cameroon. To ensure efficient preparedness and interventions in the health system, we sought to assess the knowledge of Mpox's transmission, prevention, and response among healthcare workers (HCWs) in Cameroon. Methods: A cross-sectional online survey was conducted among HCWs in Cameroon using 21-item questions adapted from the United States Centers for Disease Control and Prevention (US-CDC) standard questionnaire on Mpox. The overall knowledge of Mpox was assessed by cumulative score and categorized as excellent (≥80%, 17/21) or good (≥70%, ≥15/21) knowledge. The regression analysis was used to identify the predictors of Mpox knowledge. Results: The survey enrolled 377 participants, but only responses from 342 participants were analyzed. Overall, 50.6% were female participants, and 59.6% aged 30 years or younger. The majority of the participants were medical doctors (50.3%); most worked in central-level hospitals (25.1%) and had 1-5 years of experience (70.7%). A total of up to 92.7% were aware of Mpox, with social media (58.7%) and radio/television (49.2%) as the main sources. The mean knowledge score was 14.0 ± 3.0 (4 to 20), with only 12.9% having excellent knowledge (≥80%) and 42.1% having good knowledge of Mpox. Younger age (26-30 years old) was associated with good knowledge, while workplace type was associated with excellent knowledge of Mpox (aOR [95% CI]: 4.01 [1.43-11.24]). Knowledge of treatment/management of Mpox was generally poor across the different professional categories. Conclusion: Knowledge of Mpox among HCWs is substandard across different professionals. Thus, for optimal preparedness and immediate interventions for Mpox and similar emerging pathogens, capacity-strengthening programs should be organized for HCWs while encouraging scientific literature and organizational social media websites.


Subject(s)
Mpox (monkeypox) , Pandemic Preparedness , United States , Humans , Female , Adult , Male , Cameroon , Cross-Sectional Studies , Health Personnel
4.
Emerg Infect Dis ; 30(3): 432-443, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38325363

ABSTRACT

During 1979-2022, Cameroon recorded 32 laboratory-confirmed mpox cases among 137 suspected mpox cases identified by the national surveillance network. The highest positivity rate occurred in 2022, indicating potential mpox re-emergence in Cameroon. Both clade I (n = 12) and clade II (n = 18) monkeypox virus (MPXV) were reported, a unique feature of mpox in Cameroon. The overall case-fatality ratio of 2.2% was associated with clade II. We found mpox occurred only in the forested southern part of the country, and MPXV phylogeographic structure revealed a clear geographic separation among concurrent circulating clades. Clade I originated from eastern regions close to neighboring mpox-endemic countries in Central Africa; clade II was prevalent in western regions close to West Africa. Our findings suggest that MPXV re-emerged after a 30-year lapse and might arise from different viral reservoirs unique to ecosystems in eastern and western rainforests of Cameroon.


Subject(s)
Monkeypox virus , Mpox (monkeypox) , Humans , Cameroon/epidemiology , Monkeypox virus/genetics , Ecosystem , Mpox (monkeypox)/epidemiology , Africa, Western/epidemiology
6.
Sci Rep ; 13(1): 21654, 2023 12 08.
Article in English | MEDLINE | ID: mdl-38066020

ABSTRACT

While the SARS-CoV-2 dynamic has been described globally, there is a lack of data from Sub-Saharan Africa. We herein report the dynamics of SARS-CoV-2 lineages from March 2020 to March 2022 in Cameroon. Of the 760 whole-genome sequences successfully generated by the national genomic surveillance network, 74% were viral sub-lineages of origin and non-variants of concern, 15% Delta, 6% Omicron, 3% Alpha and 2% Beta variants. The pandemic was driven by SARS-CoV-2 lineages of origin in wave 1 (16 weeks, 2.3% CFR), the Alpha and Beta variants in wave 2 (21 weeks, 1.6% CFR), Delta variants in wave 3 (11 weeks, 2.0% CFR), and omicron variants in wave 4 (8 weeks, 0.73% CFR), with a declining trend over time (p = 0.01208). Even though SARS-CoV-2 heterogeneity did not seemingly contribute to the breadth of transmission, the viral lineages of origin and especially the Delta variants appeared as drivers of COVID-19 severity in Cameroon.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , Cameroon/epidemiology , COVID-19/epidemiology , Genomics
7.
Bull World Health Organ ; 101(3): 170-178, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36865607

ABSTRACT

Objective: To describe the implementation of case-area targeted interventions to reduce cholera transmission using a rapid, localized response in Kribi district, Cameroon. Methods: We used a cross-sectional design to study the implementation of case-area targeted interventions. We initiated interventions after rapid diagnostic test confirmation of a case of cholera. We targeted households within a 100-250 metre perimeter around the index case (spatial targeting). The interventions package included: health promotion, oral cholera vaccination, antibiotic chemoprophylaxis for nonimmunized direct contacts, point-of-use water treatment and active case-finding. Findings: We implemented eight targeted intervention packages in four health areas of Kribi between 17 September 2020 and 16 October 2020. We visited 1533 households (range: 7-544 per case-area) hosting 5877 individuals (range: 7-1687 per case-area). The average time from detection of the index case to implementation of interventions was 3.4 days (range: 1-7). Oral cholera vaccination increased overall immunization coverage in Kribi from 49.2% (2771/5621 people) to 79.3% (4456/5621 people). Interventions also led to the detection and prompt management of eight suspected cases of cholera, five of whom had severe dehydration. Stool culture was positive for Vibrio cholerae O1 in four cases. The average time from onset of symptoms to admission of a person with cholera to a health facility was 1.2 days. Conclusion: Despite challenges, we successfully implemented targeted interventions at the tail-end of a cholera epidemic, after which no further cases were reported in Kribi up until week 49 of 2021. The effectiveness of case-area targeted interventions in stopping or reducing cholera transmission needs further investigation.


Subject(s)
Cholera , Humans , Cholera/epidemiology , Cholera/prevention & control , Cameroon/epidemiology , Cross-Sectional Studies , Anti-Bacterial Agents , Chemoprevention
10.
Sci Afr ; 12: e00802, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34095639

ABSTRACT

Official case counts suggest Africa has not seen the expected burden of COVID-19 as predicted by international health agencies, and the proportion of asymptomatic patients, disease severity, and mortality burden differ significantly in Africa from what has been observed elsewhere. Testing for SARS-CoV-2 was extremely limited early in the pandemic and likely led to under-reporting of cases leaving important gaps in our understanding of transmission and disease characteristics in the African context. SARS-CoV-2 antibody prevalence and serologic response data could help quantify the burden of COVID-19 disease in Africa to address this knowledge gap and guide future outbreak response, adapted to the local context. However, such data are widely lacking in Africa. We conducted a cross-sectional seroprevalence survey among 1,192 individuals seeking COVID-19 screening and testing in central Cameroon using the Innovita antibody-based rapid diagnostic. Overall immunoglobulin prevalence was 32%, IgM prevalence was 20%, and IgG prevalence was 24%. IgM positivity gradually increased, peaking around symptom day 20. IgG positivity was similar, gradually increasing over the first 10 days of symptoms, then increasing rapidly to 30 days and beyond. These findings highlight the importance of diagnostic testing and asymptomatic SARS-CoV-2 transmission in Cameroon, which likely resulted in artificially low case counts. Rapid antibody tests are a useful diagnostic modality for seroprevalence surveys and infection diagnosis starting 5-7 days after symptom onset. These results represent the first step towards better understanding the SARS-CoV-2 immunological response in African populations.

11.
Lancet Infect Dis ; 21(8): 1089-1096, 2021 08.
Article in English | MEDLINE | ID: mdl-33773618

ABSTRACT

BACKGROUND: Real-time PCR is recommended to detect SARS-CoV-2 infection. However, PCR availability is restricted in most countries. Rapid diagnostic tests are considered acceptable alternatives, but data are lacking on their performance. We assessed the performance of four antibody-based rapid diagnostic tests and one antigen-based rapid diagnostic test for detecting SARS-CoV-2 infection in the community in Cameroon. METHODS: In this clinical, prospective, diagnostic accuracy study, we enrolled individuals aged at least 21 years who were either symptomatic and suspected of having COVID-19 or asymptomatic and presented for screening. We tested peripheral blood for SARS-CoV-2 antibodies using the Innovita (Biological Technology; Beijing, China), Wondfo (Guangzhou Wondfo Biotech; Guangzhou, China), SD Biosensor (SD Biosensor; Gyeonggi-do, South Korea), and Runkun tests (Runkun Pharmaceutical; Hunan, China), and nasopharyngeal swabs for SARS-CoV-2 antigen using the SD Biosensor test. Antigen rapid diagnostic tests were compared with Abbott PCR testing (Abbott; Abbott Park, IL, USA), and antibody rapid diagnostic tests were compared with Biomerieux immunoassays (Biomerieux; Marcy l'Etoile, France). We retrospectively tested two diagnostic algorithms that incorporated rapid diagnostic tests for symptomatic and asymptomatic patients using simulation modelling. FINDINGS: 1195 participants were enrolled in the study. 347 (29%) tested SARS-CoV-2 PCR-positive, 223 (19%) rapid diagnostic test antigen-positive, and 478 (40%) rapid diagnostic test antibody-positive. Antigen-based rapid diagnostic test sensitivity was 80·0% (95% CI 71·0-88·0) in the first 7 days after symptom onset, but antibody-based rapid diagnostic tests had only 26·8% sensitivity (18·3-36·8). Antibody rapid diagnostic test sensitivity increased to 76·4% (70·1-82·0) 14 days after symptom onset. Among asymptomatic participants, the sensitivity of antigen-based and antibody-based rapid diagnostic tests were 37·0% (27·0-48·0) and 50·7% (42·2-59·1), respectively. Cohen's κ showed substantial agreement between Wondfo antibody rapid diagnostic test and gold-standard ELISA (κ=0·76; sensitivity 0·98) and between Biosensor and ELISA (κ=0·60; sensitivity 0·94). Innovita (κ=0·47; sensitivity 0·93) and Runkun (κ=0·43; sensitivity 0·76) showed moderate agreement. An antigen-based retrospective algorithm applied to symptomatic patients showed 94·0% sensitivity and 91·0% specificity in the first 7 days after symptom onset. For asymptomatic participants, the algorithm showed a sensitivity of 34% (95% CI 23·0-44·0) and a specificity of 92·0% (88·0-96·0). INTERPRETATION: Rapid diagnostic tests had good overall sensitivity for diagnosing SARS-CoV-2 infection. Rapid diagnostic tests could be incorporated into efficient testing algorithms as an alternative to PCR to decrease diagnostic delays and onward viral transmission. FUNDING: Médecins Sans Frontières WACA and Médecins Sans Frontières OCG. TRANSLATIONS: For the French and Spanish translations of the abstract see Supplementary Materials section.


Subject(s)
Antibodies, Viral/blood , Antigens, Viral/analysis , Asymptomatic Infections , COVID-19 Serological Testing , COVID-19/diagnosis , SARS-CoV-2/immunology , Feasibility Studies , Humans , Prospective Studies , Sensitivity and Specificity
12.
Microbiol Resour Announc ; 10(10)2021 Mar 11.
Article in English | MEDLINE | ID: mdl-33707325

ABSTRACT

We describe the coding-complete genome sequence of a severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) strain obtained in Cameroon from a 58-year-old French patient who arrived from France on 24 February 2020. Phylogenetic analysis showed that this virus, named hCoV-19/Cameroon/1958-CMR-YAO/2020, belongs to lineage B.1.5 and is closely related to an isolate from France.

SELECTION OF CITATIONS
SEARCH DETAIL
...